  Parametr   Description
Type      
  Type   Connection type to Inverter
  Timeslots per day   number of time slots per day
Plant      
  Name   Name of Plant. Must be unique for account.
  Timezone   Plant timezone
  Max buy power from grid kW Parameter of plant connection to grid.
  Max sell power to grid kW Parameter of plant connection to grid.
  What % of PV is connected to the DC (direct current) side of the inverter? % 0% - all PV is connected to AC (alternating current)
100% - all PV is connected to DC (direct current)
  Latitude/Longitude   Geographic location of Plant.
Can be used: in Meteo module and in PV forecast module
Battery on plant      
  Battery kWh (brutto) kWh Battery capacity
  Average battery voltage V Use to calculate W from A and A from W. Can be approximate and rounded
  Min battery SOC % Minimal battery SOC.
Below is only the energy used for emergency purposes in the event of a power outage.
  Max inverter charge power (kW) DC kW Max inverter charge power
  Max inverter discharge power (kW) DC kW Max inverter discharge power
  Max battery BMS charge power (kW) DC kW Max battery charge power. Important if different then inverter charge power and with PV connected to DC.
  Max battery BMS discharge power (kW) DC kW Max battery discharge power. Important if different then inverter discharge power and with PV connected to DC.
  Grid to Battery charge losses (%) % Charge looses (include way how BMS calculate SOC)
  Battery to Grid/Loads discharge losses (%) % Discharge looses (include way how BMS calcaulate SOC)
Victron      
  VRM Portal Id   VRM Portal Id you can find in Cerbo -> settings -> VRM online portal -> VRM portal ID
  Installation Id   'Instalation Id' is number on VRM web address.
  VRM Login/email   Login to VRM portal
  VRM Password   Password to VRM portal if not 2FA is used
  VRM Token   Token for 2FA
  'VRM Instance' number of 'VE.Bus System' device   Normally inverter has number 276. But sometimes different.
Solarman / DeyeCloud      
  Login type   Login by email or by user name or by phone number
  Email, Login or Phone country + number   Login to Solarman/DeyeCloud
  Password   Password to Solaman/DeyeCloud
  Save login data to automatically reconnect   Keep Login and Password for relogin from time to time.
Otherwise you will have to login yourself. (You will receive email about it)
  Select inverter SerialNo   After connection SerialNumber must be selected
  Type of inverter (you can't make a mistake!)   Type of inverter connected. If you make mistake and send data to inverter than you should reset inverter to factory settings!
  Deye: Add MI/GEN production to PV production: Deye only Normally production from GEN input is added to PV production, but on some fireware is not added, so you must check this option.
  Deye: No CT, so don't try to set ZeroToCT Deye only Before discharge program remembers current Mode to return to it after end of discharge. If before discharge current Mode is 'Selling First' then program doesn't know to which More should return. So it return to ZeroToCT. If you check this option program will return to ZeroToLoad
  Deye: Set the inverter time every midnight Deye only Update inverter time at midnight
  SOC data are sending by HomeAssistant/SolarAssistant (not imported from Inverter)   Don't get SOC from inverter but SOC will be exported by HomeAssistant.
  FromGrid and ToGrid data are imported from   Don't get FromGrid/ToGrid from inverter but FromGrid/ToGrid will be export by HomeAssistant or imported from IoT meter.
  Loads data are sending by HomeAssistant/SolarAssistant (not imported from Inverter)   Don't get Loads from inverter but Loads will be epported by HomeAssistant
Backup connection - DeyeCloud   Solarman only  
  How backup connection should be used   Off - don't use DeyeCloud as backup connection
On error - use DeyeCloud if Solarman returns error
OnlyBackup - don't use Solarman but DeyeCloud, always
  Login type/Email/Password   Login and password to login to DeyeCloud
  Save login data to automatically reconnect   Save login and password to reconnect to DeyeCloud from time to time. Otherwise you will have to reconnect manually
  Select inverter SerialNo   After connection to DeyeCloud you must select inverter SerialNo
Inverter parameters   Deye only  
  Use Voltage (V) instead of SOC   Inverter use V instead of SOC in TimeOfUse
  Also calculate current SOC from V   If checked than calculate SOC from V. If not checked than get SOC directly from inverter
GbbShunt   Solarman+Deye only  
  Switch on   Switch on GbbShunt
  Battery minimal SOC (for SOC autoreset) / V when SOC is set to Minimum SOC   When V goes to 'V when SOC is set to Minimum SOC' then SOC is reset to 'Battery minimal SOC'
  Battery maximal SOC (for SOC autoreset) / V when SOC is set to Maximum SOC   When V goes to 'V when SOC is set to Maximum SOC' then SOC is reset to 'Battery maximal SOC'
  Looses on charge+discharge (%) % Looses on charge+discharge operation
  V during charge battery V V send to TimeOfUse during charge operation
  V during discharge battery V V send to TimeOfUse during discharge operation
Support      
  Send email to yourself when no connection with Plant after x hours hours After how much hours program will send email about no connection with Plant. Empty field to stop sending emails
  Send email to yourself with errors in log (checked every hour)   This send email with errors every hours
  Additional emails (for errors in log, month report)   Additional addresses to send email to. Good if you are Installer and want to send emails to Customer, or vice versa.
  Share plant to support team   Give Support Team access to your Plant. Support Team can check your Plant, but first contact with them on Discord.